The thermostat turns the boiler on and off at a predetermined temperature by responding to the water temperature. Most thermostats have two major components, a switch and a sensor. Temperature changes affect the sensor, which in turn operates the switch. The rise in temperature creates a break in an electrical circuit to turn the boiler off. when the sensor cools, the circuit is completed and the burner resumes firing.The GP Remote Probe Thermostat is a capillary tube thermostat. It relies on a viscous liquid to respond to temperature changes and open/close the switch. A capillary thermostat consists of a sensing bulb and tube with an extremely small internal diameter partially filled with a special compound, which expands when heated and activates the switch. This thermostat can be mounted at a distance from the sensing bulb.
- Panel mounted dual-scale knob
- Nickel plated probe resists corrosion
- 60 inch insulated capillary tube
- Sensing Element: Nickel-Plated Copper
| UPC | 777897142945 |
|---|---|
| Package Length (in) | 6.20" |
| Package Width (in) | 4.40" |
| Package Height (in) | 1.00" |
| Pressure Range | 4000 psi |
| Voltage Rating | 380 V |